PMID:15969817: Difference between revisions
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php |
imported>Wikientrybot change PMID template to TableEdit version |
||
| Line 1: | Line 1: | ||
{{RightTOC}} | {{RightTOC}} | ||
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.130268.A52238b89831d3--> | |||
<!-- | |||
****************************************************************************************** | |||
* | |||
* ** PLEASE DON'T EDIT THIS TABLE DIRECTLY. Use the edit table link under the table. ** | |||
* | |||
****************************************************************************************** --> | |||
{| id="A52238b89831d3" class=" tableEdit PMID_info_table" | |||
|- | |- | ||
| | !align=left |Citation | ||
|| | |||
'''No author listed''' (2005) Cobalt speciation study in the cobalt-cysteine system by electrospray ionization mass spectrometry and anion-exchange chromatography inductively coupled plasma atomic emission spectrometry. ''Appl Spectrosc'' '''59''':696-705 | |||
|- | |||
!align=left |Abstract | |||
|| | |||
This paper describes the ability of the combination of electrospray ionization mass spectrometry (ESI-MS) and anion-exchange chromatography coupled with inductively coupled plasma atomic emission spectrometry (AEC-ICP-AES) for cobalt speciation study in the binary cobalt-cysteine system. ESI-MS, allowing the identification and the characterization of the analytes, is used as a technique complementary to AEC-ICP-AES, providing elemental information on the separated species. The methods have been developed through the study of samples containing Co2+ and 1-fold to 5-fold molar ratios of cysteine over a pH range 2.5 to 11. In each case, cobalt-cysteine complexes were characterized by ESI-MS in negative ion mode. AEC-ICP-AES allowed further separation and detection of the cobalt species previously characterized. The strong influence of pH and ligand-to-metal ratios on the nature and stoichiometry of the species is demonstrated. For the first time, a direct experimental speciation diagram of cobalt species has been established owing to these analytical techniques. This work is a promising basis for the speciation analysis of cobalt, since a good knowledge of cobalt speciation is of prime importance to better understanding its fate in biological and environmental media. | |||
|- | |||
!align=left |Links | |||
|| | |||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=15969817 PubMed] | |||
Online version:[http://dx.doi.org/10.1366/0003702053945912 10.1366/0003702053945912] | |||
|- | |- | ||
|{{ | !align=left |Keywords | ||
|| | |||
Anion Exchange Resins; Binding Sites; Chromatography, Ion Exchange/methods; Cobalt/analysis; Cobalt/chemistry; Cysteine/analysis; Cysteine/chemistry; Macromolecular Substances/analysis; Macromolecular Substances/chemistry; Spectrometry, Mass, Electrospray Ionization/methods; Spectrophotometry, Atomic/methods | |||
|- class="tableEdit_footer" | |||
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.130268.A52238b89831d3&page=130268&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> || | |||
|} | |} | ||
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.130268.A52238b89831d3--> | |||
==Significance {{HelpIcon|Help:Literature}} == | ==Significance {{HelpIcon|Help:Literature}} == | ||
{{LitSignificance}} | {{LitSignificance}} | ||
Revision as of 18:46, 1 September 2013
| Citation |
No author listed (2005) Cobalt speciation study in the cobalt-cysteine system by electrospray ionization mass spectrometry and anion-exchange chromatography inductively coupled plasma atomic emission spectrometry. Appl Spectrosc 59:696-705 |
|---|---|
| Abstract |
This paper describes the ability of the combination of electrospray ionization mass spectrometry (ESI-MS) and anion-exchange chromatography coupled with inductively coupled plasma atomic emission spectrometry (AEC-ICP-AES) for cobalt speciation study in the binary cobalt-cysteine system. ESI-MS, allowing the identification and the characterization of the analytes, is used as a technique complementary to AEC-ICP-AES, providing elemental information on the separated species. The methods have been developed through the study of samples containing Co2+ and 1-fold to 5-fold molar ratios of cysteine over a pH range 2.5 to 11. In each case, cobalt-cysteine complexes were characterized by ESI-MS in negative ion mode. AEC-ICP-AES allowed further separation and detection of the cobalt species previously characterized. The strong influence of pH and ligand-to-metal ratios on the nature and stoichiometry of the species is demonstrated. For the first time, a direct experimental speciation diagram of cobalt species has been established owing to these analytical techniques. This work is a promising basis for the speciation analysis of cobalt, since a good knowledge of cobalt speciation is of prime importance to better understanding its fate in biological and environmental media. |
| Links |
PubMed Online version:10.1366/0003702053945912 |
| Keywords |
Anion Exchange Resins; Binding Sites; Chromatography, Ion Exchange/methods; Cobalt/analysis; Cobalt/chemistry; Cysteine/analysis; Cysteine/chemistry; Macromolecular Substances/analysis; Macromolecular Substances/chemistry; Spectrometry, Mass, Electrospray Ionization/methods; Spectrophotometry, Atomic/methods |
| edit table |
Significance
You can help EcoliWiki by summarizing why this paper is useful
Useful Materials and Methods
You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.
Annotations
| Gene product | Qualifier | GO ID | GO term name | Evidence Code | with/from | Aspect | Notes | Status |
|---|---|---|---|---|---|---|---|---|
| edit table |
EcoliWiki Links
Add links to pages that link here (e.g. gene, product, method pages)
References
See Help:References for how to manage references in EcoliWiki.