PMID:11936098: Difference between revisions
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php |
imported>Wikientrybot change PMID template to TableEdit version |
||
| Line 1: | Line 1: | ||
{{RightTOC}} | {{RightTOC}} | ||
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.118791.I52238310554f5--> | |||
<!-- | |||
****************************************************************************************** | |||
* | |||
* ** PLEASE DON'T EDIT THIS TABLE DIRECTLY. Use the edit table link under the table. ** | |||
* | |||
****************************************************************************************** --> | |||
{| id="I52238310554f5" class=" tableEdit PMID_info_table" | |||
|- | |- | ||
| | !align=left |Citation | ||
|| | |||
'''No author listed''' (2002) Potentiometric phosphate-sensing system utilizing phosphate-binding protein. ''Anal Bioanal Chem'' '''372''':273-5 | |||
|- | |||
!align=left |Abstract | |||
|| | |||
A phosphate-detection system has been developed which uses phosphate-binding protein (PBP) from Escherichia coli. PBP was immobilized on a sheet of nitrocellulose membrane by cross-linking and the membrane potential of the immobilized PBP was measured. The response time of the system to phosphate was 5 min. The response was selective to phosphate among other anions. Under optimum conditions 0.1-1.5 mmol L(-1) phosphate can be determined with this system. | |||
|- | |||
!align=left |Links | |||
|| | |||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=11936098 PubMed] | |||
Online version:[http://dx.doi.org/10.1007/s00216-001-1138-1 10.1007/s00216-001-1138-1] | |||
|- | |- | ||
|{{ | !align=left |Keywords | ||
|| | |||
Biosensing Techniques/methods; Calibration; Collodion/chemistry; Cross-Linking Reagents/chemistry; Escherichia coli/chemistry; Ion-Selective Electrodes; Membranes, Artificial; Phosphate-Binding Proteins/chemistry; Phosphates/analysis; Potentiometry | |||
|- class="tableEdit_footer" | |||
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.118791.I52238310554f5&page=118791&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> || | |||
|} | |} | ||
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.118791.I52238310554f5--> | |||
==Significance {{HelpIcon|Help:Literature}} == | ==Significance {{HelpIcon|Help:Literature}} == | ||
{{LitSignificance}} | {{LitSignificance}} | ||
Revision as of 18:10, 1 September 2013
| Citation |
No author listed (2002) Potentiometric phosphate-sensing system utilizing phosphate-binding protein. Anal Bioanal Chem 372:273-5 |
|---|---|
| Abstract |
A phosphate-detection system has been developed which uses phosphate-binding protein (PBP) from Escherichia coli. PBP was immobilized on a sheet of nitrocellulose membrane by cross-linking and the membrane potential of the immobilized PBP was measured. The response time of the system to phosphate was 5 min. The response was selective to phosphate among other anions. Under optimum conditions 0.1-1.5 mmol L(-1) phosphate can be determined with this system. |
| Links |
PubMed Online version:10.1007/s00216-001-1138-1 |
| Keywords |
Biosensing Techniques/methods; Calibration; Collodion/chemistry; Cross-Linking Reagents/chemistry; Escherichia coli/chemistry; Ion-Selective Electrodes; Membranes, Artificial; Phosphate-Binding Proteins/chemistry; Phosphates/analysis; Potentiometry |
| edit table |
Significance
You can help EcoliWiki by summarizing why this paper is useful
Useful Materials and Methods
You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.
Annotations
| Gene product | Qualifier | GO ID | GO term name | Evidence Code | with/from | Aspect | Notes | Status |
|---|---|---|---|---|---|---|---|---|
| edit table |
EcoliWiki Links
Add links to pages that link here (e.g. gene, product, method pages)
References
See Help:References for how to manage references in EcoliWiki.