| | !align=left |Citation | ||
|| | |||
'''Lee, HS, Kang, IM, Lee, HW, Seo, JH, Ryu, JH, Choi, SJ, Lee, MJ, Jeong, SY, Cho, YW and Lee, KT''' (2008) Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma. ''J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.'' '''863''':158-62 | |||
|- | |||
!align=left |Abstract | |||
|| | |||
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma. | |||
|- | |||
!align=left |Links | |||
|| | |||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18218344 PubMed] | |||
Online version:[http://dx.doi.org/10.1016/j.jchromb.2007.11.032 10.1016/j.jchromb.2007.11.032] | |||
|- | |- | ||
|{{ | !align=left |Keywords | ||
|| | |||
Anti-Inflammatory Agents, Non-Steroidal/blood; Calibration; Chromatography, High Pressure Liquid; Etodolac/blood; Humans; Indomethacin/blood; Indomethacin/pharmacokinetics; Quality Control; Reproducibility of Results; Tandem Mass Spectrometry | |||
|- class="tableEdit_footer" | |||
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.121543.T52238f184905c&page=121543&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> || | |||
|} | |} | ||
< | <!--box uid=d41d8cd98f00b204e9800998ecf8427e.121543.T52238f184905c--> | ||
==Significance {{HelpIcon|Help:Literature}} == | ==Significance {{HelpIcon|Help:Literature}} == | ||
{{LitSignificance}} | {{LitSignificance}} | ||
| Line 19: | Line 38: | ||
==Annotations {{HelpIcon|Help:Literature}}== | ==Annotations {{HelpIcon|Help:Literature}}== | ||
< | <annotationlinks/> | ||
==EcoliWiki Links {{HelpIcon|Help:Literature}} == | ==EcoliWiki Links {{HelpIcon|Help:Literature}} == | ||
Latest revision as of 04:33, 15 September 2013
| Citation |
Lee, HS, Kang, IM, Lee, HW, Seo, JH, Ryu, JH, Choi, SJ, Lee, MJ, Jeong, SY, Cho, YW and Lee, KT (2008) Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 863:158-62 |
|---|---|
| Abstract |
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma. |
| Links |
PubMed Online version:10.1016/j.jchromb.2007.11.032 |
| Keywords |
Anti-Inflammatory Agents, Non-Steroidal/blood; Calibration; Chromatography, High Pressure Liquid; Etodolac/blood; Humans; Indomethacin/blood; Indomethacin/pharmacokinetics; Quality Control; Reproducibility of Results; Tandem Mass Spectrometry |
| edit table |
Significance
You can help EcoliWiki by summarizing why this paper is useful
Useful Materials and Methods
You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.
Annotations
<annotationlinks/>
EcoliWiki Links
Add links to pages that link here (e.g. gene, product, method pages)
References
See Help:References for how to manage references in EcoliWiki.