PMID:17673983: Difference between revisions
Jump to navigation
Jump to search
Edited by wikibot |
Edited by wikibot |
||
| Line 1: | Line 1: | ||
{{RightTOC}} | {{RightTOC}} | ||
| Line 30: | Line 29: | ||
!Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status | !Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status | ||
|-class='sortbottom' | |-class='sortbottom' | ||
|[{{SERVER}} | |[{{SERVER}}{{SCRIPTPATH}}/index.php?title=Special:TableEdit&id=63ce1649aab8b3180235b0af7618f667.0.J47aa9bee4b21b&page=0&pagename={{FULLPAGENAMEE}} edit table] || || || || || || || || | ||
|} | |} | ||
<!--box uid=63ce1649aab8b3180235b0af7618f667.0.J47aa9bee4b21b--> | <!--box uid=63ce1649aab8b3180235b0af7618f667.0.J47aa9bee4b21b--> | ||
Revision as of 12:53, 30 April 2008
Ahmad, AI and Ghasemi, JB (2007) New unsymmetrical cyanine dyes for real-time thermal cycling.Anal Bioanal Chem 389:983-8
| Abstract | Asymmetric cyanine dyes bind to the minor groove of double stranded DNA (dsDNA) owing to their crescent configuration; therefore, these dyes are widely used as a dsDNA probes. BOXTO-MEE is derived from BOXTO by adding the polar methoxyethoxyethyl tail in order to increase solubility, dissociation rate kinetics, and stability. As a result, BOXTO-MEE showed significant reduction in nonspecific amplification (primer dimers) without significant effect on target sequence amplification, PCR efficiency, and standard curve correlation coefficient. BETIBO is another example of an asymmetric cyanine dye that can binds to dsDNA but is less efficient than BOXTO-MEE for use in real-time PCR. Statistical analysis of reproducibility results shows that BETIBO is not strong enough to be used for quantifying low nucleic acid quantities. Statistical analysis for BOXTO-MEE results shows that there is no significant difference between the efficiency and correlation coefficient achieved by BOXTO-MEE and SYBR Green I, but a significant difference in the dynamic range is observed because BOXTO-MEE has a wider dynamic range. BOXTO-MEE stock solution was stable at -20 degrees C for more than 1 year and 40 microM solution was stable for 45 days (at least) at 4 degrees C. |
| Links | PubMed |
Significance
You can help EcoliWiki by summarizing why this paper is useful
Useful Materials and Methods
You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.
Annotations
| Gene product | Qualifier | GO ID | GO term name | Evidence Code | with/from | Aspect | Notes | Status |
|---|---|---|---|---|---|---|---|---|
| edit table |
EcoliWiki Links
Add links to pages that link here (e.g. gene, product, method pages)
References
See Help:References for how to manage references in EcoliWiki.