<span style = 'font-size: large'> '''Jones, KE, Wetzler, TF and Kenny, GE'''  (1981) T1 bacteriophage as an indicator for decontamination of laminar-flow biological safety cabinets.''Appl. Environ. Microbiol.'' '''41''':1072-3</span>
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY. Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="Q522396cdaef3c"  class=" tableEdit PMID_info_table" 


{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || <protect>Type 1 coliphage dried onto a glass surface was used as an indicator to monitor decontamination of biological safety cabinets. When desiccated virus was treated with formaldehyde vapor (5,000 or 10,000 ppm) adjusted to 70 to 90% relative humidity immediately before testing, viral inactivation was slow for the first 50 min but then accelerated, being complete in the next 10 min. However, when virus was incubated in an atmosphere containing 70% humidity for 1 h before formaldehyde was added, inactivation was complete within 3 min, indicating that careful attention must be paid to relative humidity in decontamination of safety cabinets.</protect>
!align=left  |Citation
||
'''No author listed''' (1981) T1 bacteriophage as an indicator for decontamination of laminar-flow biological safety cabinets. ''Appl. Environ. Microbiol.'' '''41''':1072-3
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' || [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=7235705 PubMed]<br/>
!align=left  |Abstract
||
Type 1 coliphage dried onto a glass surface was used as an indicator to monitor decontamination of biological safety cabinets. When desiccated virus was treated with formaldehyde vapor (5,000 or 10,000 ppm) adjusted to 70 to 90% relative humidity immediately before testing, viral inactivation was slow for the first 50 min but then accelerated, being complete in the next 10 min. However, when virus was incubated in an atmosphere containing 70% humidity for 1 h before formaldehyde was added, inactivation was complete within 3 min, indicating that careful attention must be paid to relative humidity in decontamination of safety cabinets.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=7235705 PubMed] [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC243863 PMC243863]
 
|-
!align=left  |Keywords
||
Containment of Biohazards/instrumentation; Desiccation; Formaldehyde/pharmacology; Humidity; Protective Devices; Sterilization/instrumentation; T-Phages/growth & development
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.163426.Q522396cdaef3c&page=163426&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
</protect>
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.163426.Q522396cdaef3c-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:34, 1 September 2013

Citation

No author listed (1981) T1 bacteriophage as an indicator for decontamination of laminar-flow biological safety cabinets. Appl. Environ. Microbiol. 41:1072-3

Abstract

Type 1 coliphage dried onto a glass surface was used as an indicator to monitor decontamination of biological safety cabinets. When desiccated virus was treated with formaldehyde vapor (5,000 or 10,000 ppm) adjusted to 70 to 90% relative humidity immediately before testing, viral inactivation was slow for the first 50 min but then accelerated, being complete in the next 10 min. However, when virus was incubated in an atmosphere containing 70% humidity for 1 h before formaldehyde was added, inactivation was complete within 3 min, indicating that careful attention must be paid to relative humidity in decontamination of safety cabinets.

Links

PubMed PMC243863

Keywords

Containment of Biohazards/instrumentation; Desiccation; Formaldehyde/pharmacology; Humidity; Protective Devices; Sterilization/instrumentation; T-Phages/growth & development

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.