PMID:21413693: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
Fill PMID: Page!
imported>Wikientrybot
change PMID template to TableEdit version
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<protect>
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.179583.T52239192a19a6-->
<span style = 'font-size: large'> '''Woo, MA, Kim, MI, Yu, BJ, Cho, D, Kim, NJ, Cho, JH, Choi, BO, Chang, HN and Park, HG'''  (2011) Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs.''Anal. Chem.'' '''83''':3089-95</span>
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY. Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="T52239192a19a6"  class=" tableEdit PMID_info_table" 


{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || <protect>A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia.</protect>
!align=left  |Citation
||
'''No author listed''' (2011) Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs. ''Anal. Chem.'' '''83''':3089-95
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' ||
!align=left  |Abstract
*  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=21413693 PubMed]
||
A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=21413693 PubMed]
Online version:[http://dx.doi.org/10.1021/ac103350y 10.1021/ac103350y]
Online version:[http://dx.doi.org/10.1021/ac103350y 10.1021/ac103350y]
|-
!align=left  |Keywords
||
Escherichia coli/chemistry; Escherichia coli/cytology; Escherichia coli/growth & development; Humans; Hyperhomocysteinemia/blood; Luminescence; Luminescent Measurements/methods; Sensitivity and Specificity
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.179583.T52239192a19a6&page=179583&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
</protect>
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.179583.T52239192a19a6-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:12, 1 September 2013

Citation

No author listed (2011) Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs. Anal. Chem. 83:3089-95

Abstract

A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia.

Links

PubMed Online version:10.1021/ac103350y

Keywords

Escherichia coli/chemistry; Escherichia coli/cytology; Escherichia coli/growth & development; Humans; Hyperhomocysteinemia/blood; Luminescence; Luminescent Measurements/methods; Sensitivity and Specificity

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status


EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

See also

References

See Help:References for how to manage references in EcoliWiki.