PMID:18082423: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php
imported>Wikientrybot
change PMID template to TableEdit version
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.115744.Y52238ec5c7b2d-->
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="Y52238ec5c7b2d"  class=" tableEdit PMID_info_table" 


<span style = 'font-size: large'> '''Danev, R and Nagayama, K'''  (2008) Single particle analysis based on Zernike phase contrast transmission electron microscopy.''J. Struct. Biol.'' '''161''':211-8</span>
{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || We present the first application of Zernike phase-contrast transmission electron microscopy to single-particle 3D reconstruction of a protein, using GroEL chaperonin as the test specimen. We evaluated the performance of the technique by comparing 3D models derived from Zernike phase contrast imaging, with models from conventional underfocus phase contrast imaging. The same resolution, about 12A, was achieved by both imaging methods. The reconstruction based on Zernike phase contrast data required about 30% fewer particles. The advantages and prospects of each technique are discussed.
!align=left  |Citation
</noinclude>
||
'''No author listed'''  (2008) Single particle analysis based on Zernike phase contrast transmission electron microscopy. ''J. Struct. Biol.'' '''161''':211-8
|-
!align=left  |Abstract
||
We present the first application of Zernike phase-contrast transmission electron microscopy to single-particle 3D reconstruction of a protein, using GroEL chaperonin as the test specimen. We evaluated the performance of the technique by comparing 3D models derived from Zernike phase contrast imaging, with models from conventional underfocus phase contrast imaging. The same resolution, about 12A, was achieved by both imaging methods. The reconstruction based on Zernike phase contrast data required about 30% fewer particles. The advantages and prospects of each technique are discussed.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18082423 PubMed]
Online version:[http://dx.doi.org/10.1016/j.jsb.2007.10.015 10.1016/j.jsb.2007.10.015]
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' ||  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18082423 PubMed]
!align=left  |Keywords
||
Chaperonin 60/chemistry; Microscopy, Electron, Transmission/methods; Microscopy, Phase-Contrast/methods; Protein Conformation
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.115744.Y52238ec5c7b2d&page=115744&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
 
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.115744.Y52238ec5c7b2d-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:00, 1 September 2013

Citation

No author listed (2008) Single particle analysis based on Zernike phase contrast transmission electron microscopy. J. Struct. Biol. 161:211-8

Abstract

We present the first application of Zernike phase-contrast transmission electron microscopy to single-particle 3D reconstruction of a protein, using GroEL chaperonin as the test specimen. We evaluated the performance of the technique by comparing 3D models derived from Zernike phase contrast imaging, with models from conventional underfocus phase contrast imaging. The same resolution, about 12A, was achieved by both imaging methods. The reconstruction based on Zernike phase contrast data required about 30% fewer particles. The advantages and prospects of each technique are discussed.

Links

PubMed Online version:10.1016/j.jsb.2007.10.015

Keywords

Chaperonin 60/chemistry; Microscopy, Electron, Transmission/methods; Microscopy, Phase-Contrast/methods; Protein Conformation

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.