PMID:21413693: Difference between revisions
Jump to navigation
Jump to search
New PMID: Page! |
Fill PMID: Page! |
||
| Line 1: | Line 1: | ||
{{RightTOC}} | |||
<protect> | |||
<span style = 'font-size: large'> '''Woo, MA, Kim, MI, Yu, BJ, Cho, D, Kim, NJ, Cho, JH, Choi, BO, Chang, HN and Park, HG''' (2011) Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs.''Anal. Chem.'' '''83''':3089-95</span> | |||
{|{{Prettytable}} align = 'center' width= '70%' | |||
|- | |||
|{{TableHeadingColor}} |'''Abstract''' || <protect>A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia.</protect> | |||
|- | |||
|{{TableHeadingColor}} nowrap |'''Links''' || | |||
* [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=21413693 PubMed] | |||
Online version:[http://dx.doi.org/10.1021/ac103350y 10.1021/ac103350y] | |||
|} | |||
</protect> | |||
==Significance {{HelpIcon|Help:Literature}} == | |||
{{LitSignificance}} | |||
== Useful Materials and Methods {{HelpIcon|Help:Literature}}== | |||
{{LitMaterials}} | |||
==Annotations {{HelpIcon|Help:Literature}}== | |||
<protect><!--box uid=63ce1649aab8b3180235b0af7618f667.179583.Z4e41b26e6bdb5--> | |||
<!-- | |||
****************************************************************************************** | |||
* | |||
* ** PLEASE DON'T EDIT THIS TABLE DIRECTLY. Use the edit table link under the table. ** | |||
* | |||
****************************************************************************************** --> | |||
{| id="Z4e41b26e6bdb5" class=" tableEdit GO_table_reference dataTable" | |||
|- {{table heading style}} | |||
!|Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status | |||
|- class="tableEdit_footer" | |||
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=63ce1649aab8b3180235b0af7618f667.179583.Z4e41b26e6bdb5&page=179583&pagename={{FULLPAGENAMEE}}&type=0&template=GO_table_reference edit table]</span> || || || || || || || || | |||
|} | |||
<!--box uid=63ce1649aab8b3180235b0af7618f667.179583.Z4e41b26e6bdb5--></protect> | |||
==EcoliWiki Links {{HelpIcon|Help:Literature}} == | |||
{{LitLinks}} | |||
==See also== | |||
==References== | |||
{{RefHelp}} | |||
<references/> | |||
Revision as of 22:19, 9 August 2011
Woo, MA, Kim, MI, Yu, BJ, Cho, D, Kim, NJ, Cho, JH, Choi, BO, Chang, HN and Park, HG (2011) Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs.Anal. Chem. 83:3089-95
| Abstract | <protect>A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia. |
|- |bgcolor='#CCCCFF' nowrap |Links ||
Online version:10.1021/ac103350y |} </protect>
Significance
You can help EcoliWiki by summarizing why this paper is useful
Useful Materials and Methods
You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.
Annotations
| Gene product | Qualifier | GO ID | GO term name | Evidence Code | with/from | Aspect | Notes | Status |
|---|---|---|---|---|---|---|---|---|
| edit table |
EcoliWiki Links
Add links to pages that link here (e.g. gene, product, method pages)
See also
References
See Help:References for how to manage references in EcoliWiki.