PMID:18233754: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
imported>Wikientrybot
Fix links due to TableEditLinks.php changes.
Update TableEdit tables.
Line 25: Line 25:
*  
*  
****************************************************************************************** -->
****************************************************************************************** -->
{|class = 'sortable' border="2" cellpadding="4" cellspacing="0" style="margin: 1em 1em 1em 0; border: 1px #aaa solid; border-collapse: collapse;"   
{|   id="Z47a92a397e128" class=" tableEdit GO_table_reference"   
|- {{table heading style}}
|-
!|Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status
!|Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status


|-class='sortbottom'
|- class="tableEdit_footer"
|[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=63ce1649aab8b3180235b0af7618f667.0.Z47a92a397e128&page=0&pagename={{FULLPAGENAMEE}}&type=0&template=GO_table_reference edit table] || || || || || || || ||
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=63ce1649aab8b3180235b0af7618f667.0.Z47a92a397e128&page=0&pagename={{FULLPAGENAMEE}}&type=0&template=GO_table_reference edit table]</span> || || || || || || || ||
|}
|}
<!--box uid=63ce1649aab8b3180235b0af7618f667.0.Z47a92a397e128-->
<!--box uid=63ce1649aab8b3180235b0af7618f667.0.Z47a92a397e128-->

Revision as of 04:33, 9 January 2010

Gregersen, MM, Olesen, LH, Brask, A, Hansen, MF and Bruus, H (2007) Flow reversal at low voltage and low frequency in a microfabricated ac electrokinetic pump.Phys Rev E Stat Nonlin Soft Matter Phys 76:056305

Abstract Microfluidic chips have been fabricated in Pyrex glass to study electrokinetic pumping generated by a low-voltage ac bias applied to an in-channel asymmetric metallic electrode array. A measurement procedure has been established and followed carefully resulting in a high degree of reproducibility of the measurements over several days. A large coverage fraction of the electrode array in the microfluidic channels has led to an increased sensitivity allowing for pumping measurements at low bias voltages. Depending on the ionic concentration a hitherto unobserved reversal of the pumping direction has been measured in a regime, where both the applied voltage and the frequency are low, V(rms)<1.5 V and f<20 kHz , compared to previously investigated parameter ranges. The impedance spectrum has been thoroughly measured and analyzed in terms of an equivalent circuit diagram to rule out trivial circuit explanations of our findings. Our observations agree qualitatively, but not quantitatively, with theoretical electrokinetic models published in the literature.
Links PubMed

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.