PMID:9169230: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php
imported>Wikientrybot
change PMID template to TableEdit version
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.124609.K52239c213f7e2-->
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="K52239c213f7e2"  class=" tableEdit PMID_info_table" 


<span style = 'font-size: large'> '''Zhu, J, Penczek, PA, Schröder, R and Frank, J'''  (1997) Three-dimensional reconstruction with contrast transfer function correction from energy-filtered cryoelectron micrographs: procedure and application to the 70S Escherichia coli ribosome.''J. Struct. Biol.'' '''118''':197-219</span>
{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || Cryoelectron microscopy provides the means of studying macromolecules in their native state. However, the contrast transfer function (CTF) makes the images and the three-dimensional (3D) maps derived from them difficult to interpret. We developed methods to determine the CTF from experimental data and to obtain a CTF-corrected 3D reconstruction. The CTF correction and 3D reconstruction accomplished in one step make it easy to combine different defocus data sets and decrease the error accumulation in the computation. These methods were applied to energy-filtered images of the 70S Escherichia coli ribosome, resulting in a distortion-free 3D map of the ribosome at 1/24.5 A-1 resolution, as determined by the differential phase residual resolution criterion.
!align=left  |Citation
</noinclude>
||
'''No author listed''' (1997) Three-dimensional reconstruction with contrast transfer function correction from energy-filtered cryoelectron micrographs: procedure and application to the 70S Escherichia coli ribosome. ''J. Struct. Biol.'' '''118''':197-219
|-
!align=left  |Abstract
||
Cryoelectron microscopy provides the means of studying macromolecules in their native state. However, the contrast transfer function (CTF) makes the images and the three-dimensional (3D) maps derived from them difficult to interpret. We developed methods to determine the CTF from experimental data and to obtain a CTF-corrected 3D reconstruction. The CTF correction and 3D reconstruction accomplished in one step make it easy to combine different defocus data sets and decrease the error accumulation in the computation. These methods were applied to energy-filtered images of the 70S Escherichia coli ribosome, resulting in a distortion-free 3D map of the ribosome at 1/24.5 A-1 resolution, as determined by the differential phase residual resolution criterion.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=9169230 PubMed]
Online version:[http://dx.doi.org/10.1006/jsbi.1997.3845 10.1006/jsbi.1997.3845]
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' ||  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=9169230 PubMed]
!align=left  |Keywords
||
Escherichia coli/chemistry; Escherichia coli/ultrastructure; Image Processing, Computer-Assisted/methods; Macromolecular Substances; Microscopy, Electron; Models, Molecular; Particle Size; Reproducibility of Results; Ribosomes/chemistry; Ribosomes/ultrastructure
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.124609.K52239c213f7e2&page=124609&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
 
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.124609.K52239c213f7e2-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:57, 1 September 2013

Citation

No author listed (1997) Three-dimensional reconstruction with contrast transfer function correction from energy-filtered cryoelectron micrographs: procedure and application to the 70S Escherichia coli ribosome. J. Struct. Biol. 118:197-219

Abstract

Cryoelectron microscopy provides the means of studying macromolecules in their native state. However, the contrast transfer function (CTF) makes the images and the three-dimensional (3D) maps derived from them difficult to interpret. We developed methods to determine the CTF from experimental data and to obtain a CTF-corrected 3D reconstruction. The CTF correction and 3D reconstruction accomplished in one step make it easy to combine different defocus data sets and decrease the error accumulation in the computation. These methods were applied to energy-filtered images of the 70S Escherichia coli ribosome, resulting in a distortion-free 3D map of the ribosome at 1/24.5 A-1 resolution, as determined by the differential phase residual resolution criterion.

Links

PubMed Online version:10.1006/jsbi.1997.3845

Keywords

Escherichia coli/chemistry; Escherichia coli/ultrastructure; Image Processing, Computer-Assisted/methods; Macromolecular Substances; Microscopy, Electron; Models, Molecular; Particle Size; Reproducibility of Results; Ribosomes/chemistry; Ribosomes/ultrastructure

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.