PMID:18203501: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php
imported>Wikientrybot
change PMID template to TableEdit version
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.121550.T52238ef7de05a-->
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="T52238ef7de05a"  class=" tableEdit PMID_info_table" 


<span style = 'font-size: large'> '''Ujiie, A, Hasebe, H, Chiba, Y and Yanagita, N'''  (2007) [Simultaneous determination of 7 kinds of preservatives and saccharin in foods with HPLC, and identification with LC/MS/MS]''Shokuhin Eiseigaku Zasshi'' '''48''':163-9</span>
|-
!align=left  |Citation
||
'''No author listed'''  (2007) [Simultaneous determination of 7 kinds of preservatives and saccharin in foods with HPLC, and identification with LC/MS/MS]. ''Shokuhin Eiseigaku Zasshi'' '''48''':163-9
|-
!align=left  |Abstract
||
A simultaneous determination method of saccharin (SA), sorbic acid (SOA), benzoic acid (BA), p-hydroxybenzoic acid ethyl (PHBA-Et), p-hydroxybenzoic acid isopropyl (PHBA-isoPr), p-hydroxybenzoic acid propyl (PHBA-Pr), p-hydroxybenzoic acid isobutyl (PHBA-isoBu) and p-hydroxybenzoic acid butyl (PHBA-Bu) in foods by HPLC was examined. A mixture of acetonitrile-water (1:1) was used to extract these additives from foods excluding liquid foods, while acetonitrile was used to extract them from liquid foods. HPLC was performed using a TSKgel ODS80Ts (4.6 mm i.d. x 150 mm) column with a mobile phase of 0.01% formic acid solution containing 2 mmol/L-di-n-butyl (or amyl) ammonium acetate (A) and acetonitrile (B) under the following conditions: A/B = 8: 2 (0-8 min) --> 6: 4 (15-32 min). Recoveries of these additives spiked in foods were 78-120%. The determination limits were 10 microg/g. As the identification method, examination by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was used. Unknown compounds were identified by detection of product ions from their precursor ions in the negative mode with multiple reaction monitoring, m/z 182 > 106 for SA, m/z 121 > 77 for BA, m/z 111 > 67 for SOA and m/z 165 > 92 for PHBA-Et. Ratios of intensity of m/z 179 > 137 to m/z 179 > 92 were used for identification of isomers PHBA-isoPr and PHBA-Pr, and the ratios of intensity of m/z 193 > 137 to m/z 193 > 92 were used for isomers PHBA-isoBu and PHBA-Bu, because these isomers have very similar (Received December 12, 2006)
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18203501 PubMed]


{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || A simultaneous determination method of saccharin (SA), sorbic acid (SOA), benzoic acid (BA), p-hydroxybenzoic acid ethyl (PHBA-Et), p-hydroxybenzoic acid isopropyl (PHBA-isoPr), p-hydroxybenzoic acid propyl (PHBA-Pr), p-hydroxybenzoic acid isobutyl (PHBA-isoBu) and p-hydroxybenzoic acid butyl (PHBA-Bu) in foods by HPLC was examined. A mixture of acetonitrile-water (1:1) was used to extract these additives from foods excluding liquid foods, while acetonitrile was used to extract them from liquid foods. HPLC was performed using a TSKgel ODS80Ts (4.6 mm i.d. x 150 mm) column with a mobile phase of 0.01% formic acid solution containing 2 mmol/L-di-n-butyl (or amyl) ammonium acetate (A) and acetonitrile (B) under the following conditions: A/B = 8: 2 (0-8 min) --> 6: 4 (15-32 min). Recoveries of these additives spiked in foods were 78-120%. The determination limits were 10 microg/g. As the identification method, examination by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was used. Unknown compounds were identified by detection of product ions from their precursor ions in the negative mode with multiple reaction monitoring, m/z 182 > 106 for SA, m/z 121 > 77 for BA, m/z 111 > 67 for SOA and m/z 165 > 92 for PHBA-Et. Ratios of intensity of m/z 179 > 137 to m/z 179 > 92 were used for identification of isomers PHBA-isoPr and PHBA-Pr, and the ratios of intensity of m/z 193 > 137 to m/z 193 > 92 were used for isomers PHBA-isoBu and PHBA-Bu, because these isomers have very similar (Received December 12, 2006)
!align=left  |Keywords
</noinclude>
||
|-
Benzoic Acid/analysis; Chromatography, High Pressure Liquid; Chromatography, Liquid; Food Analysis/methods; Food Preservatives/analysis; Hydroxybenzoates/analysis; Saccharin/analysis; Sorbic Acid/analysis; Tandem Mass Spectrometry
|{{TableHeadingColor}} nowrap |'''Links''' ||  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18203501 PubMed]
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.121550.T52238ef7de05a&page=121550&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
 
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.121550.T52238ef7de05a-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:01, 1 September 2013

Citation

No author listed (2007) [Simultaneous determination of 7 kinds of preservatives and saccharin in foods with HPLC, and identification with LC/MS/MS]. Shokuhin Eiseigaku Zasshi 48:163-9

Abstract

A simultaneous determination method of saccharin (SA), sorbic acid (SOA), benzoic acid (BA), p-hydroxybenzoic acid ethyl (PHBA-Et), p-hydroxybenzoic acid isopropyl (PHBA-isoPr), p-hydroxybenzoic acid propyl (PHBA-Pr), p-hydroxybenzoic acid isobutyl (PHBA-isoBu) and p-hydroxybenzoic acid butyl (PHBA-Bu) in foods by HPLC was examined. A mixture of acetonitrile-water (1:1) was used to extract these additives from foods excluding liquid foods, while acetonitrile was used to extract them from liquid foods. HPLC was performed using a TSKgel ODS80Ts (4.6 mm i.d. x 150 mm) column with a mobile phase of 0.01% formic acid solution containing 2 mmol/L-di-n-butyl (or amyl) ammonium acetate (A) and acetonitrile (B) under the following conditions: A/B = 8: 2 (0-8 min) --> 6: 4 (15-32 min). Recoveries of these additives spiked in foods were 78-120%. The determination limits were 10 microg/g. As the identification method, examination by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was used. Unknown compounds were identified by detection of product ions from their precursor ions in the negative mode with multiple reaction monitoring, m/z 182 > 106 for SA, m/z 121 > 77 for BA, m/z 111 > 67 for SOA and m/z 165 > 92 for PHBA-Et. Ratios of intensity of m/z 179 > 137 to m/z 179 > 92 were used for identification of isomers PHBA-isoPr and PHBA-Pr, and the ratios of intensity of m/z 193 > 137 to m/z 193 > 92 were used for isomers PHBA-isoBu and PHBA-Bu, because these isomers have very similar (Received December 12, 2006)

Links

PubMed

Keywords

Benzoic Acid/analysis; Chromatography, High Pressure Liquid; Chromatography, Liquid; Food Analysis/methods; Food Preservatives/analysis; Hydroxybenzoates/analysis; Saccharin/analysis; Sorbic Acid/analysis; Tandem Mass Spectrometry

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.