PMID:18193205: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
/Volumes/r3/t3/ul/working/touchTables/touch_all_tables.php
imported>Wikientrybot
change PMID template to TableEdit version
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.121553.U52238eede256e-->
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="U52238eede256e"  class=" tableEdit PMID_info_table" 


<span style = 'font-size: large'> '''Dirtu, AC, Roosens, L, Geens, T, Gheorghe, A, Neels, H and Covaci, A'''  (2008) Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry.''Anal Bioanal Chem'' </span>
{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum. Figure Phenolic endocrine disruptors, such as bisphenol A, triclosan and tetrabromobisphenol A, are preferentially measured in human serum at low ng/mL range.
!align=left  |Citation
</noinclude>
||
'''No author listed'''  (2008) Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry. ''Anal Bioanal Chem'' '''391''':1175-81
|-
!align=left  |Abstract
||
This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18193205 PubMed]
Online version:[http://dx.doi.org/10.1007/s00216-007-1807-9 10.1007/s00216-007-1807-9]
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' ||  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=18193205 PubMed]
!align=left  |Keywords
||
Adult; Female; Gas Chromatography-Mass Spectrometry/instrumentation; Gas Chromatography-Mass Spectrometry/methods; Humans; Male; Middle Aged; Molecular Structure; Phenols/blood; Phenols/chemistry; Polybrominated Biphenyls/blood; Polybrominated Biphenyls/chemistry; Sensitivity and Specificity; Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods; Spectrometry, Mass, Electrospray Ionization/instrumentation; Spectrometry, Mass, Electrospray Ionization/methods; Triclosan/blood; Triclosan/chemistry
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.121553.U52238eede256e&page=121553&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
 
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.121553.U52238eede256e-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}

Revision as of 19:01, 1 September 2013

Citation

No author listed (2008) Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry. Anal Bioanal Chem 391:1175-81

Abstract

This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.

Links

PubMed Online version:10.1007/s00216-007-1807-9

Keywords

Adult; Female; Gas Chromatography-Mass Spectrometry/instrumentation; Gas Chromatography-Mass Spectrometry/methods; Humans; Male; Middle Aged; Molecular Structure; Phenols/blood; Phenols/chemistry; Polybrominated Biphenyls/blood; Polybrominated Biphenyls/chemistry; Sensitivity and Specificity; Solid Phase Extraction/instrumentation; Solid Phase Extraction/methods; Spectrometry, Mass, Electrospray Ionization/instrumentation; Spectrometry, Mass, Electrospray Ionization/methods; Triclosan/blood; Triclosan/chemistry

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

Gene product Qualifier GO ID GO term name Evidence Code with/from Aspect Notes Status

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.