PMID:15041653: Difference between revisions

From EcoliWiki
Jump to navigation Jump to search
imported>Wikientrybot
Fix links due to TableEditLinks.php changes.
imported>Wikientrybot
change PMID template to TableEdit version
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{RightTOC}}
{{RightTOC}}
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.116011.N5223883832aca-->
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|  id="N5223883832aca"  class=" tableEdit PMID_info_table" 


<span style = 'font-size: large'> '''Park, KH, Berrier, C, Martinac, B and Ghazi, A'''  (2004) Purification and functional reconstitution of N- and C-halves of the MscL channel.''Biophys. J.'' '''86''':2129-36</span>
{|{{Prettytable}} align = 'center' width= '70%'
|-
|-
|{{TableHeadingColor}} |'''Abstract''' || MscL is a mechanosensitive channel gated by membrane tension in the lipid bilayer alone. Its structure, known from x-ray crystallography, indicates that it is a homopentamer. Each subunit comprises two transmembrane segments TM1 and TM2 connected by a periplasmic loop. The closed pore is lined by five TM1 helices. We expressed in Escherichia coli and purified two halves of the protein, each containing one of the transmembrane segments. Their electrophysiological activity was studied by the patch-clamp recording upon reconstitution in artificial liposomes. The TM2 moiety had no electrophysiological activity, whereas the TM1 half formed channels, which were not affected by membrane tension and varied in conductance between 50 and 350 pS in 100 mM KCl. Coreconstitution of the two halves of MscL however, yielded mechanosensitive channels having the same conductance as the native MscL (1500 pS), but exhibiting increased sensitivity to pressure. Our results confirm the current view on the functional role of TM1 and TM2 helices in the MscL gating and emphasize the importance of helix-helix interactions for the assembly and functional properties of the channel protein. In addition, the results indicate a crucial role of the periplasmic loop for the channel mechanosensitivity.
!align=left  |Citation
</noinclude>
||
'''Park, KH, Berrier, C, Martinac, B and Ghazi, A'''  (2004) Purification and functional reconstitution of N- and C-halves of the MscL channel. ''Biophys. J.'' '''86''':2129-36
|-
!align=left  |Abstract
||
MscL is a mechanosensitive channel gated by membrane tension in the lipid bilayer alone. Its structure, known from x-ray crystallography, indicates that it is a homopentamer. Each subunit comprises two transmembrane segments TM1 and TM2 connected by a periplasmic loop. The closed pore is lined by five TM1 helices. We expressed in Escherichia coli and purified two halves of the protein, each containing one of the transmembrane segments. Their electrophysiological activity was studied by the patch-clamp recording upon reconstitution in artificial liposomes. The TM2 moiety had no electrophysiological activity, whereas the TM1 half formed channels, which were not affected by membrane tension and varied in conductance between 50 and 350 pS in 100 mM KCl. Coreconstitution of the two halves of MscL however, yielded mechanosensitive channels having the same conductance as the native MscL (1500 pS), but exhibiting increased sensitivity to pressure. Our results confirm the current view on the functional role of TM1 and TM2 helices in the MscL gating and emphasize the importance of helix-helix interactions for the assembly and functional properties of the channel protein. In addition, the results indicate a crucial role of the periplasmic loop for the channel mechanosensitivity.
|-
!align=left  |Links
||
[http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=15041653 PubMed] [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1304064 PMC1304064]
Online version:[http://dx.doi.org/10.1016/S0006-3495(04)74272-1 10.1016/S0006-3495(04)74272-1]
|-
|-
|{{TableHeadingColor}} nowrap |'''Links''' ||  [http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=pubmed&dopt=Abstract&list_uids=15041653 PubMed]
!align=left  |Keywords
||
Cloning, Molecular; Escherichia coli; Escherichia coli Proteins/chemistry; Ion Channel Gating/physiology; Ion Channels/chemistry; Liposomes/chemistry; Patch-Clamp Techniques; Recombinant Proteins/chemistry
 
|- class="tableEdit_footer"
|<span class="tableEdit_editLink plainlinks">[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=d41d8cd98f00b204e9800998ecf8427e.116011.N5223883832aca&page=116011&pagename={{FULLPAGENAMEE}}&type=1&template=PMID_info_table edit table]</span> ||
|}
|}
 
<!--box uid=d41d8cd98f00b204e9800998ecf8427e.116011.N5223883832aca-->
==Significance {{HelpIcon|Help:Literature}} ==
==Significance {{HelpIcon|Help:Literature}} ==
{{LitSignificance}}
{{LitSignificance}}
Line 18: Line 38:


==Annotations {{HelpIcon|Help:Literature}}==
==Annotations {{HelpIcon|Help:Literature}}==
<!--box uid=63ce1649aab8b3180235b0af7618f667.0.B47a93b5f3caae-->
<annotationlinks/>
<!--
******************************************************************************************
*
*  ** PLEASE DON'T EDIT THIS TABLE DIRECTLY.  Use the edit table link under the table. **
*
****************************************************************************************** -->
{|class = 'sortable' border="2" cellpadding="4" cellspacing="0" style="margin: 1em 1em 1em 0; border: 1px #aaa solid; border-collapse: collapse;" 
|- {{table heading style}}
!|Gene product!!Qualifier!!GO ID!!GO term name!!Evidence Code!!with/from!!Aspect!!Notes!!Status
 
|-class='sortbottom'
|[{{SERVER}}{{SCRIPTPATH}}?title=Special:TableEdit&id=63ce1649aab8b3180235b0af7618f667.0.B47a93b5f3caae&page=0&pagename={{FULLPAGENAMEE}}&type=0&template=GO_table_reference edit table] || || || || || || || ||
|}
<!--box uid=63ce1649aab8b3180235b0af7618f667.0.B47a93b5f3caae-->


==EcoliWiki Links {{HelpIcon|Help:Literature}} ==
==EcoliWiki Links {{HelpIcon|Help:Literature}} ==

Latest revision as of 04:23, 15 September 2013

Citation

Park, KH, Berrier, C, Martinac, B and Ghazi, A (2004) Purification and functional reconstitution of N- and C-halves of the MscL channel. Biophys. J. 86:2129-36

Abstract

MscL is a mechanosensitive channel gated by membrane tension in the lipid bilayer alone. Its structure, known from x-ray crystallography, indicates that it is a homopentamer. Each subunit comprises two transmembrane segments TM1 and TM2 connected by a periplasmic loop. The closed pore is lined by five TM1 helices. We expressed in Escherichia coli and purified two halves of the protein, each containing one of the transmembrane segments. Their electrophysiological activity was studied by the patch-clamp recording upon reconstitution in artificial liposomes. The TM2 moiety had no electrophysiological activity, whereas the TM1 half formed channels, which were not affected by membrane tension and varied in conductance between 50 and 350 pS in 100 mM KCl. Coreconstitution of the two halves of MscL however, yielded mechanosensitive channels having the same conductance as the native MscL (1500 pS), but exhibiting increased sensitivity to pressure. Our results confirm the current view on the functional role of TM1 and TM2 helices in the MscL gating and emphasize the importance of helix-helix interactions for the assembly and functional properties of the channel protein. In addition, the results indicate a crucial role of the periplasmic loop for the channel mechanosensitivity.

Links

PubMed PMC1304064 Online version:10.1016/S0006-3495(04)74272-1

Keywords

Cloning, Molecular; Escherichia coli; Escherichia coli Proteins/chemistry; Ion Channel Gating/physiology; Ion Channels/chemistry; Liposomes/chemistry; Patch-Clamp Techniques; Recombinant Proteins/chemistry

Significance

You can help EcoliWiki by summarizing why this paper is useful

Useful Materials and Methods

You can help Ecoliwiki by describing the useful materials (strains, plasmids, antibodies, etc) described in this paper.

Annotations

<annotationlinks/>

EcoliWiki Links

Add links to pages that link here (e.g. gene, product, method pages)

References

See Help:References for how to manage references in EcoliWiki.